Home AboutUs Products services news&events Dealers Education contactus
STATE OF ART INSTRUMENTATION FROM AN INNOVATIVE COMPANY
ALPHA SCINTILLATION MONITOR [ Type : AM 736 ] Print
Technical Data

Alpha Scintillation monitor type AM736 manufactured and supplied by NUCLEONIX SYSTEMS is designed around 8 bit microcontroller. It uses a ZnS (Ag) screen as the alpha scintillator which is covered with a thin aluminized mylar window to prevent light leakages. Efficiency better than 25% at centre is guaranteed with background counts being less than 0.5 CPM.
It is primarily used for routine checking of Alpha contamination on floor, work benches, walls and beams etc. in active labs. It is a micro-controller based unit designed to indicate contamination in CPS or CPM or preset scaling modes on a LCD display. It has large sensitive area of about 100 Sq.Cm. It operates on 7.5V, dry cells. Well designed handle for holding has been provided the instrument.

Features

  • Measures contamination in CPS, CPM and Preset timer modes.
  • 16x2 LCD dot matrix display.
  • Large Scintillator to cover surface area of approx. 100 Sq.Cm.
  • Designed around micro-controller
  • Efficiency : Better than 25%
  • Uses ZnS screen along with replaceable aluminized mylar.
Specifications
Radiation Detected
Alpha
Detector
Zns screen covered with aluminized mylar (serves as entrance window) coupled to 2” PMT with a suitable light guide.
User can easily replace Zns Screen when damaged. No screws are used, only latches to hold the scintillator frame.
Detector Viewing Area

100sq cm scintillator with a sensitive area of more than 80%.

PMT
2" photomultiplier tube
Typical Operating Voltage Range
750 - 900V
Modes of operation
CPS, CPM and Preset times modes.
Efficiency
Better than 25% at centre.
Background

Less than 0.5cpm.

Preset Time
(1-9999) Sec.
Counts Capacity
9999
Built-in Storage
999 readings can be stored and recalled onto display.
RS 232 (Optional)
PC connectivity through RS 232 port for dumping data.
RTC (Optional)

Real time clock for time stamp of each data.

Buzzer

Aural chirps for each radiation event will be produced.

Display
16x2, dot matrix LCD display
HV
HV adjustable internally 750V-900V (Factory Set) depending on the PMT used.
Power
Operable on standard dry cells (1.5V X 5) 7.5 volts DC, Size AA, LR6, Alkaline cells BPL Excell or its equivalent or Rechargeable NiMH (1.2Vx5)6VDC, size AA, LR6 or Battery eliminator.
Note:
1. Carrying Case (Optional): A carrying case suitable during transportation can be offerred optionally.
2. Battery eliminator can be supplied at extra cost.
Plot No.162 A & B, Phase-II, IDA, Cherlapally, Hyderabad-500051 India Phone:+91-40-27263701, 32918055, 32914548 Fax : 040 - 27262146