(A) GAMMA DETECTION SECTION
Detectors Type: High sensitivity PVT detectors coupled to PMT detector
No. of detectors per pillar: 1 no.
Volume of each detector : 10000cc
Dimensions of each detector: 1000 x 250 x 40mm
Energy range: 30 KeV to 5 MeV
Sensitivity of each detector: 250 CPS/ m R/h (Approx)
Shielding : Suitable thickness lead shielding is provided on all sides of detector except the measuring face to suppress background radiation and to enhance MDA.
High voltage and front-end electronics: High voltage and front-end electronics are all housed together in each of the detector pillar.
(b) radiation detection pillar :
(i) Each radiation detection pillar comprises of a single 10000cc large volume plastic scintillation detector along with lead shielding of suitable thickness form part of the gamma detection system (As described in section A)
ii. No. of detector pillars per system: 2
iii. Distance separation between detector pillars: 2m
iv. Height of detector pillar: 1.5m
(C) MEASUREMENT & ALARM UNIT:
This unit essentially comprises of advanced electronic circuits with embedded code built-in to receive data from the gamma detector assembly and correct for background levels and generate audio/visual alarms in the event counts due to package monitoring exceed the preset levels set.
Alarm data is automatically transferred at the end of monitoring to the central PC for further investigation by the duty personnel.
Background Updation: Automatic background measurement by sensing the detection area is unoccupied by using occupancy sensors.
Alarm Setting Adjustment: Automatically adjusted based on the current background level.
No. of monitoring channels: 2
Display: 20 x 4 LCD display
|
User Interface: Front panel keypad (password protected) or through PC
Measurement Unit: CPS or CPM
Measurement Range: 0 to 99999 CPS or 0 to 999999 CPM.
Alarm Range: 0 to 99999 CPS or 0 to 999999 CPM.
Occupancy Sensing: Using IR/proximity sensors to detect vehicle presence.
Detection Area & Performance criteria:
Vertical : 0 - 1.5m
Horizontal : 0 - 2m (Parallel to the direction of movement)
Audio/ Visual Alarms: Hooter and sounder have been provided for the purpose of generation of audio/visual alarms.
Package Identification (optional): Images /Photographs of all the packages scanned for radioactivity are captured automatically by a camera and stored along with the corresponding readings. (D) COMPUTER SOFTWARE & PC CONFIGURATION:
The data acquisition and control application software running on the host PC with a WINDOWS XP OS will communicate with the processing electronics through RS232/Ethernet port. This software facilitates remote configuration of paramters, live acquisition of data and analysis of profile for localization of any contamination.
The software is extremely flexible allowing the user to easily configure the system general operations like adjustment of detector parameters and accessing of database of all the individual vehicle scans. The software is so designed that it does not require the duty personnel to understand physics to operate the equipment.
PC Configuration:
Standard PIV configuration with WINDOWS XP/2000 operating system (PC not within scope of supply) |