RAD CHECK METER - [ Type : RC705B ] Print
Technical Data

Rad Check Meter Type : RC 705B manufactured by NUCLEONIX SYSTEMS is primarily designed to measure low level Radioactive
Contamination (RaC) in steel, castings and other alloy and machined parts. It is an ideal choice for all export houses who are into
the above line of products. This Portable Meter uses a sensitive scintillator with PMT as the detector. This meter gives an optimum
performance in counting Low-Level Gamma Radiative Contamination (RaC) in a variety of situations. RC 705B measures contamination in CPS, CPM and Doserate ( ìR/h,ìSv/h) modes and has built in user presettable alarm facility to declare the product as contaminated. Unit gives audio /visual alarms once it exceeds preset level. It is advised to preset the alarm atleast 1.5 times
background radiation level, at that place.

Features

  • Ideal choice for checking Radioactive Contamination (RaC) in Steel, Foundry and engineering industrial products.
  • Microcontroller based design Compact, elegant and light weight.
  • Has Four modes of measurement CPS, CPM, mR / hr and mSv/hr
  • User settable alarm facility
  • Highly sensitive compared to other similar meters.
  • Choice of Two Detectors : (1" X 1") or (2" X 2") Scintillator couple to PMT.
RC705B with Internal Probe
RC705B with Extermal Probe
Specifications
Detector

Scintillator coupled to a Photo multiplier Tube.
Options:
A. Built in detector scintillator size 1 " X 1"
B. External detector with scintillator size 2" X 2"

Accuracy
Better than +/- 15% with Cs-137 (above 100 mR/hr)
Better than +/- 25% with Cs-137 (upto 100 mR/hr)
Measurement Modes

CPS, CPM, (0-10000) mR/h or (0-99999)nSv/h

Range Changeover
Automatic
Preset alarm level range
User settable, over the entire range.
Sensitivity
a. 1 mR/h or 10nSv/h, in terms of Radiation unit.
b. Interms of minimum measurable RaC, it can detect 30 KBq of Co60 contamination homogeneously distributed in a Steel sample upto 10 cm away with internal probe arrangement and upto 20 cm with external probe arrangement.
Display Indication
Dot matrix LCD display for doserate .
Time Constant (TC)
LO, MED, HI
Audio Output
Built-in piezo electric buzzer..
Serial Port / Data Communication
Built-in serial port facilitates data downloading into PC.
User Interface
i. Power ON/OFF switch
ii. START, STOP, PROG, p & qcommand buttons for setting of parameters and operation of the instrument.
Power
Operable on standard dry cells (105V x 5) 7.5 volts DC, Size AA, LR6 Alkaline cells BPL Excell or its equivalent or Rechargeable NiMH (1.2V x 5 )6V DC, size AA, LR6 or Battery eliminator.
AC adaptor working on 230V AC shall be supplied optionally.
Fault Diagnostics
Low battery and EHT failure indication is provided.
Dimensions
106W x 196L x 100Ht in mm (Approx.)