Technical Data

PACKAGE MONITORING SYSTEM Type: PMS 1009 manufactured by NUCLEONIX has been primarily designed to detect Low level of Radioactive contamination (RaC) in baggages/packages.

This system could be used to detect radioactive contamination present in a package comprising of steel / alloy finished goods, atutomotive component / part / other precision machained parts, Engineering components etc., meant for exports.

Inspection of outgoing packed boxes, for radioactive contamination, could be carriedout, at the final QA floor shop/dept.

Package Monitoring System. Type: PMS 1009 is offered as a following configurations for steel industry.

(a) Twin gamma detector pillar arrangement (1.5 mtr Ht) The gamma detection system essentially comprises of a single large volume of plastic scintillation detector housed inside each detector pillar. A large PVT detectors having a active volume of 10000cc are housed inside each detector pillar.

Each gamma detector is provided with necessary lead shielding to minimize the background and to enhance the MDA of the system.

The gamma assembly is housed inside a low Z material based detector pillar.

Two such detector pillars are placed along either side of the passage where the package is going to pass. This installed monitor automatically detects the presence of radioactive material in the package if it exceeds preset levels. The monitoring system does this by measuring the radiation level taken while package occupies detection area and comparing this level to the background radiation level that is measured and updated while detection area is unoccupied.

The background radiation levels are continuously measured and automatic adjustment of alarm thersholds enables a constant statistical false alarm rate to be maintained during the system use. Occupancy sensors are used to detect the presence or absence of packages as it passes through the monitor to know when to monitor the background and when to monitor the package.

The sensitivity of detectors is dependent upon the closeness of the detector and source as well as the slowness with which they pass each other. For packages two detector pillars are recommended and maximum distance between pillars is 2m. Additionally barriers not obstructing the view of the monitor are to be installed to protect monitor from being damaged by forklifts.

The performance and effectiveness of the installed instrument is strongly dependent on its ability to measure radiation intensity over the search area of interest. As such based on this requirement detector volumes, geometry and dimensions have been adopted.

Alarm indications and displays are available locally and are clearly visible to the officers manning the inspection point and are also available remotely at the central monitoring PC.

This system could be installed at various entry/exit points of the installation and can be under the supervision of security officer.

PACKAGE MONITORING SYSTEM
Large Volume Plastic Scintillator based Detector Pillars (Size: 1.57 mtr.Height, 300 mm Width, 70 mm Length)
Specifications

(A) GAMMA DETECTION SYSTEM

Detector Type: High sensitivity PVT detectors coupled to
PMT detector
No. of detectors per pillar: 1 no.
Volume of each detector : 10000cc
Dimensions of each detector: 1000 x 250 x 40mm
Energy range: 30 KeV to 5 MeV
Sensitivity of each detector: 250 CPS/ìR/h (Approx)
Shielding : Suitable thickness lead shielding is provided
on all sides of detector except the measuring face to
suppress background radiation and to enhance MDA.
High voltage and front-end electronics: High voltage and
front-end electronics are all housed together in each of the
detector pillar.

(B) RADIATION DETECTION PILLAR :

(i) Each radiation detection pillar comprises of a single
10000cc large volume plastic scintillation detector along
with lead shielding of suitable thickness form part of the
gamma detection system (As described in section A)
ii. No. of detector pillars persystem: 2
iii. Distance seperation between detector pillars: 2m
iv. Height of detector pillar: 1.5m

(C) MEASUREMENT & ALARM UNIT:

This unit essentially comprises of advanced electronic
circuits with embedded code built-in to receive data from
the gamma detector assembly and correct for background
levels and generate audio/visual alarms in the event counts due to package monitoring exceed the preset levels set.
Alarm data is automatically transferred at the end of
monitoring to the central PC for further investigation by the
duty personnel.
Background Updation: Automatic background measurement by sensing the detection area is unoccupied by using occupancy sensors.
Alarm Setting Adjustment: Automatically adjusted based
on the current background level.

No. of monitoring channels: 2
Display: 20 x 4 LCD display
User Interface: Front panel keypad (password protected)
or through PC
Measurement Unit: CPS or CPM
Measurement Range: 0 to 99999 CPS or 0 to 999999
CPM.
Alarm Range: 0 to 99999 CPS or 0 to 999999 CPM.
Occupancy Sensing: Using IR/proximity sensors to detect
vehicle presence.
Detection Area & Performance criteria:
Vertical : 0 - 1.5m
Horizontal : 0 - 2m (Parallel to the direction of movement)
Audio/ Visual Alarms: Hooter and sounder have been
provided for the purpose of generation of audio/visual
alarms.
Package Identification (optional): Images /Photographs
of all the packages scanned for radioactivity are captured
automatically by a camera and stored along with the
corresponding readings.

(D) COMPUTER SOFTWARE & PC CONFIGURATION:


The data acquisition and control application software
running on the host PC with a WINDOWS XP OS will
communicate with the processing electronics through
RS232/Ethernet port. This software facilitates remote
configuration of paramters, live acquisition of data and
analysis of profile for localization of any contamination.
The software is extremely flexible allowing the user to easily
configure the system general operations like adjustment
of detector parameters and accessing of database of all
the individual vehicle scans. The software is so designed
that it does not require the duty personnel to understand
physics to operate the equipment.
PC Configuration:
Standard PIV configuration with WINDOWS XP/2000
operating system (PC not within scope of supply)