Digital Pocket Dosimeter Type PD716 uses Si-diode as the radiation detector. This serves as personnel radiation monitor with alarm to cater to the needs of radiation workers in Nuclear installations, Reprocessing plants, Radiochemical plants, etc. It also finds use in medical, industrial, other applications where radioactive isotopes are used for a variety of applications.
It measures integrated radiation dose in the range of 1 µSv to 99.99mSv and doserate in the range of 00.1mSv/h to 99.99 mSv/h. It is also provided with preset alarm feature for generation of audio alarms in the event of high dose / doserate. The user interface to the instrument is through the LCD display and a single push button switch. The dosimeter is provided with an optical port for data communication with PC for the purpose of setting preset alarm levels and for calibration of the dosimeter.
Its design is based on nano watt technology resulting in a battery life of better than 2000 Hrs of continuous use. Additional options : i. Docking station for PD716 . ii. Dose records data management software DS717.Features
Specifications
Radiation Detected | Gamma / X-ray |
---|---|
Detector | Si diode |
Dark current : | Dark current is 1µSv (CaSO4) equivalent with software-based sampling & subtraction. |
Display | 4 digit 7 segment LCD display |
Energy dependence | +/– 25% in the range of 60 keV to 1.33 MeV |
Range changeover | Automatic |
Dose | 1mSv to 999.9 mSv |
Dose rate | 00.01 mSv/hr to 999.9mSv/hr. |
Over range | 100% over range compliant |
Alarm Settings | a) Dose : 1µSv-999999 mSv. b) Doserate : 1µSv-99999 µSv/h. |
Dose History | Facilitates storage of dose profile at adjustable time intervals. |
Audio Alarm | 1 Hz alternating short beeps for dose rate and long beeps for dose alarm. Additionally vibration alert is provided for alarm annunciation. |
PC connectivity | Optical port for communication with PC for configuration, calibration & data transfer. |
Batteries | 2 × 1.5 V AA size alkaline /any batteries to provide a life of approximately 2000 Hrs. |
Battery status | Low battery indication on LCD |
Electronics | PIC microcontroller based design. |
Control | A single push button for a) Powering the unit ON/OFF. b) Viewing dose / doserate. c) Muting doserate/dose alarm. |
EMI /EMC compliance | Shall not be affected by RF over frequency of 20 MHz to 1000 MHz at an intensity of 10V/m as per ANSI N42.17A. Tolerant to mobile phone interference. |
Dimensions | 67W x 28H x 92L. |
Weight | 150gms. approximatly. |