Digital Pocket Dosimeter – I (Digidose) [ TYPE : PD 714 ]
Technical Data

Digital Pocket Dosimeter Type PD714 uses a high sensitive Si- diode as the radiation detector. This is designed to fit into pocket & has a spring loaded clip. This serves as personnel radiation Dosimeter to cater to the needs of radiation workers in Nuclear installations, Reprocessing plants, Radiochemical plants etc. It also finds use in medical, industrial, other applications where radioactive isotopes are used for a variety of applications.
It is also recommended as a personal dosimeter in Radiotherapy departments, nuclear medicine centres, cyctron & PET-CT centres. It measures integrated radiation dose in the range of 1µSv to 999.9mSv and doserate in the range of 00.01mSv/h to 999.9 mSv/h. The user interface to the instrument is through the LCD display and a single push button switch. Its design is based on nano watt technology resulting in a battery life of better than 500 Hrs of continuous use.Additional options : i. Docking station for PD714 ii. Dose records data management software DS715.
Features
Specifications
Radiation Detected | Gamma / X-ray |
---|---|
Detector | Si diode |
Dark current : | Dark current is 1µSv (CaSO4) equivalent with software-based sampling & subtraction. |
Display | 4 digit 7 segment LCD display |
Energy dependence | +/– 25% in the range of 60 keV to 1.33 MeV |
Range changeover | Automatic |
Dose | 1mSv to 999.9 mSv |
Dose rate | 00.01 mSv/hr to 999.9mSv/hr. |
Over range | 100% over range compliant |
PC connectivity | Optical port for communication with PC for configuration, calibration & data transfer. |
Residual Signal : | 8 to 12% of initial TL in the linear dose range specified |
Batteries | 3V Li-coin cell Type CR2354 size -23.4mm x 5.4 battery to provide a life of approximately 500 Hrs. |
Battery status | Low battery indication on LCD |
Electronics | PIC microcontroller based design. |
Control | i. A single push button for a) Powering the unit ON b) Viewing dose / doserate ii. IR interface with PC a. Setting / Reading ID of dosimeter in stored in memory b. Setting / Reading issued / not issued status stored in memory. c. Reading current dose reading d. Resetting dose reading e. Powering OFF the dosimeter |
EMI /EMC compliance | Shall not be affected by RF over frequency of 20 MHz to 1000 MHz at an intensity of 10V/m as per ANSI N42.17A. Tolerant to mobile phone interference. |
Dimensions | 31.5(W) x 124(L) x 14.5(D) mm, excluding clip |
Weight | Approximately 60 gm. |